The new software version V2.3 contains major improvements in optical modelling. You now have access to all common dispersion functions and effective medium approaches. Special types of anisotropy are supported. Variable angle spectroscopic ellipsometry is possible. Parametric plots and multiple plots with two parameters are enabled. The mapping now delivers additional maps of uncertainty and mean square error together with the map of the resulting fit parameter. An intelligent filter removes the spikes of unmapped points in maps.
-

EP³View Kinetics Software 1.0

EP³View Kinetics Software 1.0 provides the tools for the complete recording, visualization and evaluation of time-resolved multi-channel ellipsometric measurements, e.g. for protein interaction kinetics on microarrays.
As an AddOn to the Nanofilm EP³View, Kinetics Software 1.0 imports all relevant data during measurements and allows extensive online and post-run analysis.
-

EP³-BAM Tools & Z-lift

As you probably know your EP³ already includes a Brewster Angle Microscope (BAM) for visualization of monolayers on liquid surfaces. In order to optimize the operation of your EP³ as a BAM we introduce our new software AddOn and Z-lift
-

Laser safety cabinet

The Laser safety cabinet serves two purposes in one. It protects the instrument from dust and air convection at the same time protecting the user from scattered laser light. The acrylic glas is colored to absorb the laser wavelength, still allowing visual control of the instrument.

The laser interlock closes a mechanical shutter if the doors are opened.
-

Laser Selection Guide

Apart from the standard recommended internal laser of 532nm for highly reflecting samples it is possible to equip the EP3 with different lasers.

External lasers via fiber coupler:
405nm, 488nm, 514nm
532nm, 543nm, 594nm
633nm, 658nm, 690nm
780nm, 830nm, 905nm
accessories - solid/liquid cells, z-lift, software add ons and many more...

Imaging optics

High resolution

objectivearea resolutionlim. angle
10x0.44 mm 2 µm 68 deg.
20x0.22 mm1 µm60 deg.

-

Medium resolution

objectivearea resolutionlim. angle
2x2.50 mm 4 µm 70 deg.
5x0.89 mm3 µm70 deg.

The limiting angle is for samples larger than approx. 40 mm diameter.

Large Area Imaging

area remarks
25x40 mm² includes LA illumin. optics not with spectroscopy

-

Sample holder

The sample holder depends on the specific application.
As a standard, the EP3 comes without a sample holder.

Please contact us for a solution.
-

Computer controlled x/y/z-stage

We offer a choice of precision x/y-stages. These high quality stages are computer controlled and allow automatic mapping of large samples.

moving range100 mm (x/y) 30 mm (z)
repeatability1 µm (x/y)

-

Automatic sample alignment stage ALS

The ALS stage is a very useful device to conveniently align the sample to a horizontal position, which is critical for a precise measurement. The ALS is in particular useful if large samples are to be mapped automatically.
-

Beam Cutter

In case of measurements on transparent substrates (e.g. glass, mica, etc.) one part of the incident beam is reflected on the top side of the substrate, the other part of the beam is transmitted into the substrate, where it is reflected off of the bottom of the substrate. Thus, the image quality of the upper reflected beam is decreased when interference with the bottom reflected beam occurs. Nanofilm’s beam cutter can be put half into the beam, before the beam meets the sample, in order to generate a dark area where the bottom side reflected beam is cut off.
-

Vario antivibration isolation systems

We offer state-of-the-art active vibration isolation systems as accessory for our EP³. These modular systems electronically eliminate critical floor vibrations in sensitive experiments, for example at air/liquid interfaces. Recommended type is the halcyonics_variobasic40_100.
-

OptiSlides

The new OptiSlides from Nanofilm are especially designed glass slides with optimal optical properties for measurements of bio-relevant layers - e.g. proteins, DNA, lipids, etc. Their advanced optical properties enable ellipsometric measurements on glass substrates in liquid ambient conditions with the highest sensitivity.
SPR-kinetic cell - available with Peltier temperature controll-

Cells

SPR-cell for surface plasmon resonance measurements

The EP3 can be used as an SPR-Microscope without any technical modification
Inclusive prismBK7 (n=1.5) or SF10 (n=1.7)
Sample dimensions15 x 22 x 1...10 mm³ to 26 x 76 x 1...10 mm³
Area of detection4 x 8 mm
Field of view 2 x 3 mm (2x objective)
Liquid volume0.1 ml + tubing
External cooling optional possible 5°C - 85°C

SPR-kinetic cell - available with Peltier temperature controll

EC-SPR cell

The electro chemical Kinetics / SPR cell is based on Nanofilm’s Kinetics / SPR cell with additional electrodes. Therefore, electrochemical and ellipsometrical sample evaluation can be done in parallel. The sample should be transparent and a conductive surface is required. By ellipsometrical examination an adsorption of organic material (e.g. proteins) on the sample’s surface can be recorded.

The materials of this cell are biocompatible and suited for water based liquids like salt solutions, buffers etc.
-

SL-cell for ellipsometry in liquid ambient

Many applications of Ellipsometry involve the liquid/solid interface, for example corrosion and adsorption processes.

MaterialPeek®, Teflon®, Viton®
Volume0.7 ml + tubing

Windows

AR-coated glass, BK7
Sample dimensions5 x 22 x 1...10 mm³ - 26 x 76 x 1...10 mm³
External cooling optional possible5°C - 75°C

-

EC-Solid liquid cell

The electro chemical solid liquid cell is especially designed for electro chemical measurements on a non-transparent sample in liquid ambient. The working electrode is on the sample surface. The materials of this cell are suited for water based liquids like salt solutions, buffers etc.
-

Liquid Handling

The liquid handling system consists of a valve unit, a peristaltic pump, tubings and a measuring chamber. It is especially designed for kinetic measurements in liquid ambient like protein-protein interactions with the EP³. All materials are biocompatible.
-

Peltier temperature control device

The peltier temperature control is a powerful tool. It can be ordered as option to the SL cell or Kinetics/SPR cell.
-
YouTube
Accurion EP4 modelling software
Optical modelling software for imaging ellipsometry from Accurion.
Please click for an introduction of the EP4Model, a powerful modelling software for analysis of ellipsometric data.
nanofilm accesories:Cells, sample handling, objectives and more
© 2011 · Accurion GmbH · Phone Headquarter Accurion Germany +49-(0)551-99960-0 · Accurion USA +1-(408) 245 8100 · Accurion Asia +91 98 450 04273